Home
World Journal of Advanced Engineering Technology and Sciences
International, Peer reviewed, Referred, Open access | ISSN Approved Journal

Main navigation

  • Home
    • Journal Information
    • Abstracting and Indexing
    • Editorial Board Members
    • Reviewer Panel
    • Journal Policies
    • WJAETS CrossMark Policy
    • Publication Ethics
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Become a Reviewer panel member
    • Join as Editorial Board Member
  • Contact us
  • Downloads

ISSN: 2582-8266 (Online)  || UGC Compliant Journal || Google Indexed || Impact Factor: 9.48 || Crossref DOI

Fast Publication within 2 days || Low Article Processing charges || Peer reviewed and Referred Journal

Research and review articles are invited for publication in Volume 18, Issue 2 (February 2026).... Submit articles

Establishment of transition point in operating mode for Constant Current Constant Voltage (CC-CV) charging of Li-ion batteries

Breadcrumb

  • Home
  • Establishment of transition point in operating mode for Constant Current Constant Voltage (CC-CV) charging of Li-ion batteries

Amit Kumar De 1, * and Shobhana Dey 2

1 Electrical and Electronics Engineering, Birla Institute of Technology, Mesra, Ranchi, India.
2 Mineral Processing Division, CSIR-National Metallurgical Laboratory, India.

Research Article
 
World Journal of Advanced Engineering Technology and Sciences, 2021, 03(01), 072-083.
Article DOI: 10.30574/wjaets.2021.3.1.0053
DOI url: https://doi.org/10.30574/wjaets.2021.3.1.0053

Received on 23 June 2021; revised on 22 August 2021; accepted on 24 August 2021

The present-day Li-ion batteries when operated, needs precise monitoring of the charging voltage. Several charging techniques have been tested so far with varying degrees of success. One of the most widely used charging techniques is the CC-CV (constant current constant voltage) charging. When performing this, the safety considerations must be maintained with respect to over voltage charging which is a very common problem during constant current charging. In order to prevent over voltage charging, the charging mode must be then shifted from CC to CV mode. So, this transition point of the charging mode from CC to CV is very crucial for the safe operation and health of the battery in the long run. The problem is that, this transition point doesn’t remain the same for the battery. So, in this paper the factors on which it depends are discussed and a Li-ion battery was charged in a few different charging rates using the CC-CV technique to demonstrate the process.

Constant current charging; Constant voltage charging; SoC estimation; Battery safety; Charging rate

https://wjaets.com/sites/default/files/fulltext_pdf/WJAETS-2021-0053.pdf

Get Your e Certificate of Publication using below link

Download Certificate

Preview Article PDF

Amit Kumar De and Shobhana Dey. Establishment of transition point in operating mode for Constant Current Constant Voltage (CC-CV) charging of Li-ion batteries. World Journal of Advanced Engineering Technology and Sciences, 2021, 03(01), 072-083. https://doi.org/10.30574/wjaets.2021.3.1.0053

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content


Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


Copyright © 2026 World Journal of Advanced Engineering Technology and Sciences

Developed & Designed by VS Infosolution