Home
World Journal of Advanced Engineering Technology and Sciences
International, Peer reviewed, Referred, Open access | ISSN Approved Journal

Main navigation

  • Home
    • Journal Information
    • Abstracting and Indexing
    • Editorial Board Members
    • Reviewer Panel
    • Journal Policies
    • WJAETS CrossMark Policy
    • Publication Ethics
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Become a Reviewer panel member
    • Join as Editorial Board Member
  • Contact us
  • Downloads

ISSN: 2582-8266 (Online)  || UGC Compliant Journal || Google Indexed || Impact Factor: 9.48 || Crossref DOI

Fast Publication within 2 days || Low Article Processing charges || Peer reviewed and Referred Journal

Research and review articles are invited for publication in Volume 18, Issue 2 (February 2026).... Submit articles

Non-invasive blood pressure measurement from the finger using an optical system based on dynamic light scattering

Breadcrumb

  • Home
  • Non-invasive blood pressure measurement from the finger using an optical system based on dynamic light scattering

Stanley A. Omenai *

Department of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.

Review Article
 
World Journal of Advanced Engineering Technology and Sciences, 2024, 12(02), 479–485.
Article DOI: 10.30574/wjaets.2024.12.2.0323
DOI url: https://doi.org/10.30574/wjaets.2024.12.2.0323

Received on 15 June 2024; revised on 27 July 2024; accepted on 30 July 2024

This paper review presents the results of a Novel method for non-invasive blood pressure measurement from the finger using an optical system based on dynamic light scattering developed by Elfi-Tech's innovative technology group [1].
A small-scaled, optical, mobile device that measures BP at the finger using dynamic light scattering was developed. The device is positioned at the base of the index finger and contains a ring with an inflatable cuff with two miniaturized dynamic light scattering (mDLS) sensors situated away from, but close to the cuff. The cuff is inflated to above systolic pressure, and changes in blood flow (hemodynamics) are measured during deflation of the cuff.
Blood Pressure measurement is carried out using specially designed algorithms based on hemodynamic indexes and waveform analysis which capture systolic and diastolic points in real-time.

Photoplethysmography; Dynamic Light Scattering; Mean Absolute Error; Hemodynamics; Diastolic; Systolic; Inflatable Cuff

https://wjaets.com/sites/default/files/fulltext_pdf/WJAETS-2024-0323.pdf

Get Your e Certificate of Publication using below link

Download Certificate

Preview Article PDF

Stanley A. Omenai. Non-invasive blood pressure measurement from the finger using an optical system based on dynamic light scattering. World Journal of Advanced Engineering Technology and Sciences, 2024, 12(02), 479–485. Article DOI: https://doi.org/10.30574/wjaets.2024.12.2.0323

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content


Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


Copyright © 2026 World Journal of Advanced Engineering Technology and Sciences

Developed & Designed by VS Infosolution