Home
World Journal of Advanced Engineering Technology and Sciences
International, Peer reviewed, Referred, Open access | ISSN Approved Journal

Main navigation

  • Home
    • Journal Information
    • Abstracting and Indexing
    • Editorial Board Members
    • Reviewer Panel
    • Journal Policies
    • WJAETS CrossMark Policy
    • Publication Ethics
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Become a Reviewer panel member
    • Join as Editorial Board Member
  • Contact us
  • Downloads

ISSN: 2582-8266 (Online)  || UGC Compliant Journal || Google Indexed || Impact Factor: 9.48 || Crossref DOI

Fast Publication within 2 days || Low Article Processing charges || Peer reviewed and Referred Journal

Research and review articles are invited for publication in Volume 18, Issue 3 (March 2026).... Submit articles

Quantifying the response modification factor of RC buildings: A comparative study using nonlinear pushover analysis

Breadcrumb

  • Home
  • Quantifying the response modification factor of RC buildings: A comparative study using nonlinear pushover analysis

Fathi M Layas 1, *, Vail Karakale 2, Fuat Aras 2 and Kamil Demircan 3

1 Department of Civil Engineering, Faculty of Engineering, University of Benghazi, Benghazi Libya. 
2 Department of Civil Engineering, Faculty of Engineering and Natural Sciences, Istanbul Medeniyet University, Istanbul,34720, Turkey.
3 TCDD Teknik, Aziziye, Hosdere Cd No :167,06690 Cankaya, Ankara, Turkey.
 

Research Article

 

World Journal of Advanced Engineering Technology and Sciences, 2026, 19(01), 190-201

Article DOI: 10.30574/wjaets.2026.19.1.0206

DOI url:https://doi.org/10.30574/wjaets.2026.19.1.0206

Received on 02 March 2026; revised on 10April 2026; accepted on 13April 2026

Earthquake-resistant design relies on controlled inelastic structural behavior, typically incorporated into seismic codes through the response modification factor (R), which reduces elastic force demands by accounting for ductility, overstrength, and energy dissipation. However, extensive research indicates that the assumed ductility levels in code-based R values are often not representative of older reinforced concrete (RC) buildings lacking proper seismic detailing, particularly in high-risk regions such as Istanbul. This study evaluates the applicability of conventional R-factor assumptions for an existing six-story RC residential building constructed in the 1980s in Istanbul’s Kadıköy district. Nonlinear static pushover analysis was employed to assess the building’s lateral load capacity and inelastic performance under two contrasting scenarios: a code-based high ductility assumption (R = 8) and a reduced, more conservative value (R = 3).
Results demonstrate that the higher R value leads to seismic demand estimates slightly below the structural capacity, falsely indicating adequate performance and safety, which contradicts observed earthquake damage patterns in the studied structure. In contrast, the lower R value produces demand levels significantly exceeding the building’s capacity, aligning more closely with real damage observations and highlighting deficiencies in ductility and torsional resistance due to structural irregularities. These findings are consistent with prior studies emphasizing the sensitivity of R to detailing quality and structural configuration. The study underscores that adopting high R values for substandard existing buildings can result in unconservative and potentially unsafe design assessments. It is therefore recommended that reduced R values—on the order of 3 or lower—be adopted for existing RC structures in high seismic zones to better reflect their actual inelastic capacity and ensure more reliable performance evaluation.
 

Response modification factor (R); Nonlinear static pushover analysis; Seismic performance; Ductility; Torsional resistance

https://wjaets.com/sites/default/files/fulltext_pdf/WJAETS-2026-0206.pdf

Get Your e Certificate of Publication using below link

Download Certificate

Preview Article PDF

Fathi M Layas, Vail Karakale, Fuat Aras and Kamil Demircan. Quantifying the response modification factor of RC buildings: A comparative study using nonlinear pushover analysis. World Journal of Advanced Engineering Technology and Sciences, 2026, 19(01), 190-201. Article DOI: https://doi.org/10.30574/wjaets.2026.19.1.0206

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content


Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


Copyright © 2026 World Journal of Advanced Engineering Technology and Sciences

Developed & Designed by VS Infosolution